MFC with high measurement accuracy and repeatability.
TECHNICAL CHARACTERISTICS:
- Burkert Type 8626
- Item number: 257009 (00257009)
- 8626-03.6M-O2.-E-A -GM82-VDFF-D-02.0
Burkert Type 8626 mass flow meters are compact devices that monitor the mass flow of gases. They maintain the set flow rate regardless of obstacles such as pressure drops or temporary flow resistance. Flow controllers consist of a flow meter, an electronic module, and a proportional valve. The built-in sensors operate in CTA mode (constant temperature anemometers). In this case, the electric heating resistor and the measuring resistor are adjusted to a constant temperature difference. Both resistors are located directly in the gas flow, and three resistors are located outside it. All resistors are connected in an electrical bridge. The first resistor in the liquid flow measures the temperature of the liquid. A second low-resistance resistor is constantly heated to maintain a clearly defined excess temperature relative to the liquid temperature. Since the resistors are located directly in the channel, the devices have excellent dynamics: the response time when the set or actual value changes is a few hundredths of a second. In addition, the sensor is practically immune to contamination.