The integrated PI controller provides excellent MFC control characteristics.
TECHNICAL SPECIFICATIONS:
- Burkert Type 8626
- Item number: 265371 (00265371)
- 8626-03,0M-N2.-E-DP-GM82-VAFF-D-04.0PC64
Burkert Type 8626 mass flow meters are compact devices that control the mass flow of gases. They control the set flow rate regardless of obstacles such as pressure drops or temporary flow resistance. Flow controllers consist of a flow meter, an electronic module, and a proportional valve. The integrated sensors operate in constant temperature anemometer mode. In this case, the electrical heating resistor and the measuring resistor are adjusted to a constant temperature difference. Both resistors are located directly in the gas flow; three more resistors are located outside it. All resistors are connected in an electrical bridge. The first resistor in the fluid flow measures the temperature of the fluid. The second resistor, which has low resistance, is constantly heated to maintain a precisely set temperature that exceeds the temperature of the liquid. Because the resistors are located directly in the channel, the devices have excellent dynamics: the response time when the setpoint or actual value changes is a few hundredths of a millisecond. In addition, the sensor is virtually free of contamination.