Nominal flow range from 20 l/min to 1500 l/min.
TECHNICAL SPECIFICATIONS:
- Burkert Type 8626
- Item number: 288791 (00288791)
- 8626-50.0L-CO2-E-DP-GM84-VDFF-B-02.0NF64
Type 8626 mass flow meters are compact devices that control the mass flow of gases. They regulate the set flow rate regardless of obstacles such as pressure drops or temporary flow resistance. The flow controllers consist of a flow meter, an electronic module, and a proportional valve. The built-in sensors operate in CTA mode (constant temperature anemometers). In this case, the electrical thermal resistance and measuring resistance are set to a constant temperature difference. Both resistors are located directly in the gas flow; three additional resistors are located outside it. All resistors are connected in an electrical bridge. The first resistor in the liquid flow measures the temperature of the liquid. A second low-resistance resistor is continuously heated to maintain a precisely set temperature that exceeds the temperature of the liquid. Since the resistors are located directly in the channel, the device has excellent dynamics: the response time when changing the set or actual value is only a few hundredths of a second. In addition, the sensor is virtually immune to contamination.