MFC with high measurement accuracy and repeatability.
TECHNICAL SPECIFICATIONS:
- Burkert Type 8626
- Item number: 290619 (00290619)
- 8626-50.0L-CO2-E-A -GM82-VAFF-B-02.0NF64
Burkert Type 8626 mass flow controllers (MFC) are compact devices that control the mass flow of gases. They regulate the set flow rate despite obstacles such as pressure loss or temporary flow resistance. The flow controller consists of a flow meter, an electronic module, and a proportional valve. Built-in sensors operate in CTA mode (constant temperature anemometer). In this case, the electric heating resistor and measuring resistor are set to a constant temperature difference. The resistors are located either directly in the gas flow or three resistors are located outside it. All resistors are connected in an electrical bridge. The first resistor in the liquid flow measures the temperature of the liquid. The second low-resistance resistor is continuously heated to maintain a precisely defined excess temperature relative to the fluid temperature. Since the resistors are located directly in the channel, the device has excellent dynamics: the response time when changing the setpoint or actual value is a few hundredths of a second. In addition, the sensor is virtually immune to contamination.